diff artifacts/src/main/java/org/dive4elements/river/artifacts/services/DischargeTablesOverview.java @ 6301:20a32dbdbb59

Remove discharge table scaling but add reference system to W - Discharge_Tables are now always W[cm] Q[m³] no need for special case handling depending on historical / master tables - W now has a referenceSystem value that can be CENTIMETER_AT_GAUGE or METER_OVER_REFPOINT. The default is METER_OVER_REFPOINT as this is the case for everything except the objects created from discharge tables Known issue: WINFO input validation is currently broken as it still scales the user input.
author Andre Heinecke <aheinecke@intevation.de>
date Wed, 12 Jun 2013 10:54:27 +0200
parents af13ceeba52a
children fe7e9da6312a
line wrap: on
line diff
--- a/artifacts/src/main/java/org/dive4elements/river/artifacts/services/DischargeTablesOverview.java	Wed Jun 12 16:36:34 2013 +0200
+++ b/artifacts/src/main/java/org/dive4elements/river/artifacts/services/DischargeTablesOverview.java	Wed Jun 12 10:54:27 2013 +0200
@@ -147,14 +147,7 @@
 
         double[][] xy = null;
 
-        if (dt.getKind() == DischargeTables.MASTER) {
-            xy = DischargeTables.loadDischargeTableValues(dt,
-                DischargeTables.MASTER_SCALE);
-        }
-        else {
-            xy = DischargeTables.loadDischargeTableValues(dt,
-                DischargeTables.HISTORICAL_SCALE);
-        }
+        xy = DischargeTables.loadDischargeTableValues(dt);
 
         XYSeries series = new XYSeries(createSeriesTitle(callMeta, dt), false);
         for (int i = 0, n = xy[0].length; i < n; i++) {

http://dive4elements.wald.intevation.org