Remove discharge table scaling but add reference system to W
- Discharge_Tables are now always W[cm] Q[m³] no need for
special case handling depending on historical / master tables
- W now has a referenceSystem value that can be CENTIMETER_AT_GAUGE or
METER_OVER_REFPOINT. The default is METER_OVER_REFPOINT as this is
the case for everything except the objects created from discharge tables
Known issue: WINFO input validation is currently broken as it still scales
the user input.
author | Andre Heinecke <aheinecke@intevation.de> |
---|---|
date | Wed, 12 Jun 2013 10:54:27 +0200 |
parents | 5aa05a7a34b7 |
children |
line wrap: on
line source
For the artifact database # su - postgres $ createuser --no-createrole --no-superuser --pwprompt --no-createdb artifacts $ createdb --encoding=UTF-8 --owner artifacts artifactsdb For the flys database # su - postgres $ createuser --no-createrole --no-superuser --pwprompt --no-createdb flys $ createdb --encoding=UTF-8 --owner flys flystest1 Build an importer package: mvn -f pom.xml clean compile assembly:single Alternatively with oracle: mvn -f pom-oracle.xml clean compile assembly:single Standalone DateGuesser testing example: mvn -e -Dexec.mainClass=de.intevation.flys.utils.DateGuesser -Dexec.args="110803" exec:java <<EOF 110803 EOF Some importer allow standalone usage: mvn -e -Dexec.mainClass=de.intevation.flys.importer.parsers.AtFileParser -Dexec.args=/home/felix/.bashrc exec:java