view etl/src/main/resources/sql/flys-common.properties @ 8578:4eb1a3c71579

(issue1753) Implement PDF export of SQ Measurement data. The SQRelationExporter now consists of two reports (to avoid subreport woes). The old SQReleation PDF only takes the Page count of the Measurement attachment as argument to correctly print the page numbers. Otherwise it is unchanged. The new SQMeasurements report lists the measured data points on which the calculation was based.
author Andre Heinecke <andre.heinecke@intevation.de>
date Mon, 16 Mar 2015 11:35:19 +0100
parents e5675e85ac38
children
line wrap: on
line source
select.rivers = \
    SELECT r.id AS id, r.name AS name, min(wcv.position) AS min_km, max(wcv.position) AS max_km \
    FROM rivers r \
        JOIN wsts w ON r.id = w.river_id \
        JOIN wst_columns wc ON w.id = wc.wst_id \
        JOIN wst_column_values wcv ON wcv.wst_column_id = wc.id \
    WHERE w.kind = 0 \
    GROUP BY r.id, r.name
select.gauges = \
    SELECT id, name, official_number, station \
    FROM gauges \
    WHERE river_id = :river_id
next.gauge.id = \
    SELECT NEXTVAL('GAUGES_ID_SEQ') AS gauge_id
insert.gauge = \
    INSERT INTO gauges (id, name, river_id, station, aeo, official_number, datum) \
    VALUES(:id, :name, :river_id, :station, :aeo, :official_number, :datum)
select.timeintervals = \
    SELECT id, start_time, stop_time FROM time_intervals
next.timeinterval.id = \
    SELECT NEXTVAL('TIME_INTERVALS_ID_SEQ') AS time_interval_id
insert.timeinterval = \
    INSERT INTO time_intervals (id, start_time, stop_time) \
    VALUES (:id, :start_time, :stop_time)
next.discharge.id = \
    SELECT NEXTVAL('DISCHARGE_TABLES_ID_SEQ') AS discharge_table_id
insert.dischargetable = \
    INSERT INTO discharge_tables \
    (id, gauge_id, description, bfg_id, kind, time_interval_id) \
    VALUES (:id, :gauge_id, :description, :bfg_id, 1, :time_interval_id)
select.discharge.table.values = \
    SELECT id, w, q FROM discharge_table_values WHERE table_id = :table_id
next.discharge.table.values.id = \
    SELECT NEXTVAL('DISCHARGE_TABLE_VALUES_ID_SEQ') AS discharge_table_values_id
insert.discharge.table.value = \
    INSERT INTO discharge_table_values (id, table_id, w, q) \
    VALUES (:id, :table_id, :w, :q)
delete.discharge.table.value = \
    DELETE FROM discharge_table_values WHERE id = :id
select.gauge.discharge.tables = \
    SELECT \
        dt.id          AS id, \
        dt.description AS description, \
        ti.start_time  AS start_time, \
        ti.stop_time   AS stop_time, \
        dt.bfg_id      AS bfg_id \
    FROM discharge_tables dt \
    LEFT OUTER JOIN time_intervals ti ON dt.time_interval_id = ti.id \
    WHERE dt.gauge_id = :gauge_id AND dt.kind = 1
select.gauge.master.discharge.table = \
    SELECT \
        dt.id AS id, \
        dt.bfg_id AS bfg_id \
    FROM discharge_tables dt JOIN gauges g ON dt.gauge_id = g.id \
    WHERE g.id = :gauge_id AND dt.kind = 0
update.bfg.id.discharge.table = \
    UPDATE discharge_tables SET bfg_id = :bfg_id WHERE id = :id
delete.discharge.table.values = \
    DELETE from discharge_table_values where table_id = :id
delete.discharge.table = \
    DELETE from discharge_tables where id = :id and kind = 1

http://dive4elements.wald.intevation.org